7 Electrical connection
7.6.8 Device address of the electronics
module
The device address of the module can be adjusted
using the rotary switch S1.
Using the module as a ...
Device address
Electronic Module D1
vamp
air
A
7.6.9 Electr. fuses in the electronics module
DANGER
- a fuse replacement may only be
carried out on a disconnected 230 V AC power
supply by qualified personnel.
Fuse Rating
Size
Assignment
F1
0.4 AT
5x20 mm
Primary-side
supply transformer
F2
4 AT
5x20 mm
Relay outputs
F3
0.4 AT
5x20 mm
Secondary-side
supply transformer
If fuse F1 or F3 is defective, a message will be shown
on the display of the control system
eco
manager-
touch
:
Electronics module communication error
7.7 Outside temperature sensor - position
Fig. 2-42_001BM
7.8 Connecting the control to the internet
To enable the Internet connection of the
eco
manager-
touch
boiler control, connect the Ethernet port
X2
1
(type RJ45) on the bottom of the display by cable to a
network router.
The connection is required in order to use the following
functions:
–
mySOLARFOCUS app
–
Weatherman function
–
Screen IP-VNC - Remote access to the control
–
Sending e-mails
i
Additional information on these functions can
be found in the operation manual.
Display - Connections
Fig. 2-43: Connections on the underside of the display
7.9 Smart Grid Ready
The SG-Ready label is a label for heat pumps, the con-
troller of which meet the conditions for inclusion in a
future, intelligent power grid
(smart grid
= SG).