4 Prior to assembly
Power 9 kW: Connect wires A1 and B1 parallel to L1,
A2 and B2 to L2, A3 and B3 to L3.
►
Insert the capillary tube sensor of the
overtemperature reset on the bottom of the
heating element into the tube (about 20 cm).
Attach the capillary tube
1
to the cable with a
cable tie
2
.
Fig. 2-22
Attach the flow sensor to the heating ele-
ment
►
Insert sensor
1
for the
flow temperature - heat
pump T1
on the top of the heating element.
Fig. 2-23_003BE
Wire guide
►
Run the capillary tube on the left side of the con-
denser, not at the flow heating circuit.
►
Provide sufficient mobility of the cables and lines
(due to oscillating positioning of the heat pump
unit).
Fig. 2-24: Cable management
16
Installation manual
vampair