7 Electrical connection
n
Use a bus cable with this specification:
–
Cable length up to 100 m: 2x2x0.22 mm²
Cable length 100 m to 200 m: 2X2x0.34 mm²
(e.g. Lapp Unitronic Bus Can, No. 2170263)
–
AWG22, STP (=Shielded Twisted Pair)
–
Nominal resistance: 120 Ohm
–
Line capacitance per metre: < 60 pF/m
–
Loop resistance: < 160 Ohm/km
n
Connect the shield of the bus cable to the ground
(GND
⏊
) of each electronic module (see the
images in the following chapter
Bus terminator
).
n
If there are several bus subscribers, the following
applies: The bus wiring must run from one bus-par-
ticipant to the next. The order of the participants
does not matter.
Fig. 2-41_Bus topology
7.6.3 Bus terminator resistance
–
CAN (Controller Area Network) is a 2-wire bus sys-
tem. The bus must be equipped at each end with a
120Ω terminating resistor (to avoid reflections).
–
Two plugs for the CAN bus -
CAN-IN
and
CAN-
OUT
- are located on the electronics module. The
terminating resistor is pre-installed to
CAN-OUT
at
the factory.
–
If only one electronic module is connected to the
heat pump, the terminating resistor for the
electronics module must be left on the
CAN-OUT
plug.
If several modules are connected, then
the terminating resistor may only be installed
on the last module in the chain
(the terminating
resistor must be removed from the remaining
modules). See the following image(s).
Heat pump vamp
air
A 120 Ohm resistor is fixedly installed in the display.
7.6.4 Connect the primary circuit circulation
pump
vamp
air
K 08, K 10:
Wilo-Yonos PARA (iPWM
pump)
►
Connect pump to the electronic module D1
Wire
Electronic module
Power cable
L
o1
– L
N
o1
- neutral conductor N
PE
o1
– protective earthing PE
Control cable
blue
OUT1
- ground
⏊
brown
OUT1
- O
black
OUT1
- I
vamp
air
K 12, K 15:
Wilo-Stratos PARA
►
Connect pump to the electronic module D1
Wire
Electronic module
Power cable
L
o1
– L
N
o1
- neutral conductor N
PE
o1
- protective earth conductor
PE
Control cable
brown
OUT1
- ground
⏊
white
OUT1
- O
28
Installation manual
vampair
Содержание vampair K 08
Страница 25: ...7 Electrical connection Installation manual vampair 25 7 4 Electrical connection plan...