CAT5/6 standard cables have eight wires (four twisted pairs), as shown in the diagram below. Wire colors
may differ from one cable to another. You can use either wiring standard, as long as both sides of the
cable have the same pin-out and color-coding.
RJ45 Pin #
Wire Color
1
10Base-T Signal
100Base-TX Signal
T568B
T568A
1
White/Orange
White/Green
T
2
Orange
Green
Transmit-
3
White/Green
White/Orange
4
Blue
Blue
Reserved
5
White/Blue
White/Blue
Reserved
6
Green
Orange
Received-
7
White/Brown
White/Brown
Reserved
8
Brown
Brown
Reserved
Figure 34: Standard cable wiring
6. Use a pre-crimped cable to connect via gland #1 to the RJ45 plug on the inverter's communication
board or, if using a spool of cable, connect as follows:
a. Insert the cable through gland #1.
b. Remove the cable’s external insulation using a crimping tool or cable cutter and expose eight
wires.
c. Insert the eight wires into an RJ45 connector, as described in
Figure 34
d. Use a crimping tool to crimp the connector.
e. Connect the Ethernet connector to the RJ45 port on the communication board.
Figure 35: The RJ45 Ethernet connection
1
The inverter connection does not support RX/TX polarity change. Supporting crossover Ethernet cables depends on the
switch capabilities.
SolarEdge
-
StorEdge Installation Guide MAN-01-00262-1.0
74
Creating an Ethernet (LAN) Connection