l
Hardware IDs
: Displays the following HW serial numbers (if exist, and connected to the inverter):
o
ID
: the inverter's ID
o
RGM1
: A preassembled RGM or any external electricity meter (with lower Modbus ID)
o
RGM2
: A second external electricity meter (with the higher Modbus ID)
o
ZB
: Zigbee MAC address
o
Cell
: MEID (CDMA) or IMEI (GSM)
o
WiFi
: Wi-Fi MAC address
Status Screens - Operational Mode
Additional presses display the following screens one after the other.
Initial Status
V a c [ V ] V d c [ V ] P a c [ W ]
2 4 0 . 7 3 7 1 . 9 2 3 4 9 . 3
P _ O K : X X X / Y Y Y < S _ O K >
- - - - - - - - - - - - - - - -
O N
l
Vac [V]
: The AC output voltage
l
Vdc [V]
: The DC input voltage
l
Pac [W]
: The AC output power
Main Inverter Status
V a c [ V ] V d c [ V ] P a c [ W ]
2 4 0 . 7
W
3 7 1 . 9
3 2 1 0 . 0
F a c [ H z ] O P s _ O k T e m p
5 0 . 0
W W W
1 1
W W W
2 8 . 2
l
Vac [V
: The AC output voltage.
l
Vdc [V]
: The DC input voltage.
l
Pac [W]
: The AC output power.
l
Fac [Hz]
: The AC output frequency.
l
OPs_Ok
: Number of optimizers sending telemetries (indicating that they are paired)
l
Temp [C or F]
: The inverter heat sink temperature
Chapter 7: User Interface
SolarEdge
-
StorEdge Installation Guide MAN-01-00262-1.0
49
Содержание storedge
Страница 1: ...SolarEdge StorEdge Installation Guide For North America Version 1 0 ...
Страница 95: ......