2. Select
Energy Manager
. The following screen is displayed:
L i m i t C o n t r o l < D i s >
E n e r g y C t r l < D i s >
S t o r a g e C o n t r o l
Limit Control
: For power limitation (including export limitation) configuration. This option can be
used in parallel to energy control. For more information refer to
http://www.solaredge.com/files/pdfs/products/feed-in_limitation_application_note.pdf
.
o
E
: Export (Feed-in) limit
o
P
: Production limit
o
Dis
: Disabled - no limit
Energy Control
: The method by which to manage the energy.
Storage Control
: Enables reserving a minimum battery charge level.
3. Select
Energy Ctrl.
. The following is displayed, showing the SolarEdge applications:
M a x S e l f - c o n s u m e
T i m e o f U s e
B a c k u p O n l y
D i s a b l e
Max Self-consume
(MSC): Maximize Self-consumption .
Time of Use
(TOU): Profile Programming.
Backup Only
: Supply power to loads during power outage.
Disable
: No energy control, that is, the battery is not used.
To set up maximum self-consumption:
1. Access the
Energy Control
menu as described above.
2. Select
Max Self-Consume
. The Energy Manager screen changes to display the following:
L i m i t C o n t r o l < D i s >
E n e r g y C t r l < M S C >
S e t O p e r a t i o n
S t o r a g e C o n t r o l