Problem
Description or possible cause
Troubleshooting
Figure 9
) to supply power to the loads
until the inverter problem is solved.
Then move to position 1.
No power to the backup loads
while grid is OFF (power outage)
The backed-up loads are not
backed up
o
Check that the inverter is
producing power
o
Check that there are no errors on
the inverter LCD
o
Check the circuit breakers on the
backed-up loads AC panel
o
Check that the AC breaker in the
StorEdge Connection Unit are in
the UP position (see
Figure 9
)
o
Check that the AC bypass switch
in the StorEdge Connection Unit is
set to position 1 (see
Figure 9
) .
Inverter without auto-transformer
(On-grid only) - The inverter does
not start production and
Error 182
Auto-Transformer Temp. Too
High
is displayed
The thermal sensor cables are not
connected.
Move the DIP switch SW2 in the
StorEdge Connection Unit to the
UP position (ON) (refer to
DIP Switch
Setup according to System Application
on page 38).
Error Codes
The error messages include an error number and a description, and have the following format:
E
r
r
o
r C
o
d
e X
X
X
(
3
x
D
2
)
<
L
i
n
e 1
>
<
L
i
n
e 2
>
XXX
: The error number. The error code numbers may differ depending on the inverter
type (single phase or three phase) as described in the table below.
(#-X#)
: A code indicating the source of error and the error information sent to the
monitoring server. This information is used by SolarEdge Support for advanced
troubleshooting..
Line 1-2
: Error description
WARNING!
All Warnings and Cautions in this manual should be adhered to while troubleshooting an error.
Tous les avertissements et précautions mentionnés dans ce manuel doivent être aussi appliqués
en cas de dépannage.
Appendix A: Troubleshooting
SolarEdge
-
StorEdge Installation Guide MAN-01-00262-1.0
83
Содержание storedge
Страница 1: ...SolarEdge StorEdge Installation Guide For North America Version 1 0 ...
Страница 95: ......