97
17. SETTING-OUT MEASUREMENT
5. Press
[H.ROTA]
to automatically rotate the SRX
until the angle of the setting out point reads 0°.
Position the target on the line of sight and press
[DIST]
to begin distance measurement.
The distance and direction to move the target until
the setting out point is located is displayed on the
SRX. The sighting point measurement results
(currently installed position of the target) are
displayed.
• <Set out Coords> can also be displayed by
selecting "Set out coords" in <Setting out>.
• Switch between the tabs to display different sets
of information.
Move the target closer/further away and upward/
downward to find the correct distance (0 is
displayed) to the setting out point.
Movement indicators: "17.2 Distance Setting-
out Measurement" step 5
Содержание SRX1
Страница 2: ...Li ion S Li ion This is the mark of the Japan Surveying Instruments Manufacturers Association ...
Страница 69: ...61 13 ANGLE MEASUREMENT The displayed horizontal angle HAR is the included angle between two points ...
Страница 175: ...167 29 REGULATIONS CE Conformity Declaration ...
Страница 176: ...29 REGULATIONS 168 ...
Страница 177: ...169 29 REGULATIONS ...
Страница 182: ...MEMO ...
Страница 183: ...JAPAN ...
Страница 184: ...1st ed 01 0609 Printed in Japan 2006 SOKKIA CO LTD ...