Vega-MV Router Multiviewer - User Manual
Issue 1 Revision 2
Page 68
© 2017 SAM
The Web Interface
Web Interface 7.1
7.1 The Web Interface
The Vega-MV unit is configured via a browser using web pages hosted by the Vega-MV unit’s
MV-CTL card.
Ensure that the MV-CTL card rear ethernet connector has a LAN connection (see section 4.6
for the MV-CTL RJ45 LAN connector location).
Note:
Java must first be installed on the PC or Mac that is to be used. This is available as a free
download from:
www.java.com/en/download/manual.jsp
Note:
Java Certificates:
Java certificates should not need to be imported, but if the certificate is not already on the
system being used, then Java will ask for permission to continue before starting the applet
(the certificate required is stored in the Vega-MV unit).
If 'Run' is selected without ticking the box for 'Always trust content from this publisher',
then the certificate will not be installed, but the applet will run.
It is best to tick the box so that the certificate is installed to avoid seeing the same message
next time the browser is to be accessed (assuming that the same system is to be used).
Note:
•
The default IP address of the MV-CTL card fitted in the frame is 192.168.0.121.
•
Depending on the system being used to access the web interface, one or more
factors such as Windows security, third party security products, firewalls and
browser security settings may prevent the applet loading from the Vega-MV unit.
For example, if using Microsoft Internet Explorer 7, the security setting should be
no higher than 'Mid'.
•
If Java platform 1.7.0_21 or later is being used Java will try to connect to the
internet to check if the application security certificate has been revoked. If the
Vega-MV unit is not connected to the internet the check will timeout after 30
Seconds and a dialog will be displayed saying the certificate cannot be verified with
an option to confirm that the application should still be run. Confirm and the Java
application will be launched. See Appendix D.3 for full details and also how to avoid
this delay if the Vega-MV unit is never connected to the internet.
•
If the Java applet reports an error the computer may be trying to use an
incompatible cached version of the MV-CTL applet.
See “Why does the Java applet report an error or say 'Program Will Not Load'
when launching the web interface?” in Appendix D.3 for the solution.