Vega-MV Router Multiviewer - User Manual
Issue 1 Revision 2
Page 209
© 2017 SAM
Commands
Hydra Open Protocol A.5
A.5.3 Source related commands
A.5.3.1
Set Source Name
Set the UMD text for a source
For each source, specify the:
•
Module name (currently ignored by the Vega-MV).
•
Source number (0 to n).
•
Name of the source.
The name given will be applied to the first line of the UMD in any objects displaying this
source. It is volatile, meaning that it only remains applied to the UMD while the current layout
remains on screen. Uploading a new layout or even uploading the current layout again will
overwrite the UMD with the text stored in the layout.
A.5.3.2
Set Source Tally
Set the tallies for a source
Note:
Source numbers are 0 based and therefore start a 0.
Send/Receive
Description
Send
<COMMAND ID=”setsourcename” SERIAL=”example”>
<MODULE ID=”module1”>
<SOURCE ID=”5”>
<NAME>Source5</NAME>
</SOURCE>
<SOURCE ID=”11”>
<NAME>Source11</NAME>
</SOURCE>
</MODULE>
<MODULE ID=”module2”>
<SOURCE ID=”8”>
<NAME>Source8</NAME>
</SOURCE>
</MODULE>
</COMMAND>
Receive
<COMMANDRESULT SERIAL=”example” ERROR=”0”>
</COMMANDRESULT>
Table 82
Set Source Name