Vega-MV Router Multiviewer - User Manual
Issue 1 Revision 2
Page 60
© 2017 SAM
Front Panel
Front Panel Operation 6.1
Display Screen:
Description
Setting
Temp:
Shows the internal temperature measured within the
Vega-MV unit, on the MV-NET card. (ºC)
Typical value = 40ºC
I/O:
Shows the maximum value of internal temperatures
measured within the Vega-MV unit, on any card. (ºC)
Typical value = 75ºC
Genlock:
Unit’s genlock and reference input status.
OK
Reference Input signal is present and unit’s genlock is
locked.
NO
Reference input not detected or unit’s genlock not locked.
LTC:
Unit’s LTC input status.
OK
LTC input detected and unit locked to LTC.
NO
LTC input not detected or unit not locked to LTC.
Fans:
Fans status:
Second display line, speed:
The speed of the fans is shown as a nominal percentage of
the fan’s full speed.
0%
Fans at idle speed. I.e. running with minimal air flow.
33%
Fans running at one third of full speed.
100%
Fans running at full speed.
Third display line, fault:
For a fan fault, the fan number is shown:
Fan N Fault
Where N is the fan number, 1 to 5.
For example, “Fan 3 Fault”.
(See Figure 49 for fans locations.)
Table 15
General Status Display Screen - Bottom Line
Figure 49 Fan Numbers
FAN 1
FAN 2
FAN 3
FAN 4
FAN 5