Object Menu
Web Interface 7.6
Setting
Description
Timer Mode
Timer Mode
radio buttons: used to select which mode the timer works in.
•
Start at a certain time of day
- triggers the timer at the time of day set in the
Start at
field. The
Start at
field is only available when this timer mode is
selected.
•
Control with GPIs
- allows the timer to be controlled by GPI inputs. The
Reset
at
field is only available when this timer mode is selected.
Countdown first
tick box: used to modify the selected timer mode operation.
•
Start at a certain Time of day
mode selected and
Countdown first
ticked:
While the time of day is earlier than the selected
Start at
time, the timer will
count down the time remaining until the
Start at
time. Once the
Start at
time is reached the timer will then count up until the
Stop at
time is
reached. When the
Stop at
time is reached the timer will then commence a
countdown of the time remaining until the
Start at
time.
•
Start at a certain Time of day
mode selected and
Countdown first
not
ticked:
The timer will display 00:00:00 during the period preceding the
Start at
time and will then count up until it reaches the
Stop at
time. Once it
reaches the
Stop at
time the timer will again display 00:00:00 until the
Start at
time.
•
Control with GPIs
selected and
Countdown first
ticked: When the reset
GPI is operated the timer will start counting down to 00:00:00 from the
value entered in the
Reset
to
field. When the timer reaches 00:00:00 it will
then count up until it is the reset GPI is activated at which point it will count
down from the value set in the
Reset to
field. The pause and resume
GPI(s) are used to pause the timer count.
•
Control with GPIs
selected and
Countdown first
not ticked:
When the reset GPI is operated the timer will start counting up from the
value set in the
Reset to
field. Operating the reset GPI again will start the
count again from the value set in the
Reset to
field. The pause and resume
GPI(s) are used to pause the timer count.
Show frames
tick box: used to select whether frames per second are also displayed.
•
Show frames
not ticked: the display format is hh:mm:ss.
•
Show frames
ticked: The display format is hh:mm:ss:ff.
The frames per second count is determined by the video output frame rate.
Where
hh
= Hours in 24 hour format
mm
= Minutes
ss
= Seconds
ff = Frames
Table 57 Edit Object - Properties - Timer Sub-Tab