Vega-MV Router Multiviewer - User Manual
Issue 1 Revision 2
Page 104
© 2017 SAM
Module Menu
Web Interface 7.3
7.3.2.2
Source Properties - Alarm Tab
The Alarm Tab allows each video and audio alarm to be configured, enabled and displayed.
The properties section of this window allows each alarm to be set individually for onset and
auto-clear delay, logging status and visibility in objects and lists.
To select an alarm to configure, click on it in the Select Alarm list on the left on the window.
The selected alarm will appear with its descriptive text highlighted in red. Choose the required
properties from the right hand section of the window and check the Enabled box to activate
the alarm.
Enabled alarms are shown with a green circle before the descriptive text.
Figure 78 Source Properties - Alarm Tab.
Setting
Description
Select alarm
Click on one of the alarms listed to change the attributes of it using the
controls listed under Properties.
Enabled
Tick this to enable the selected alarm.
Delay
Input a delay before the alarm starts.
Automatic clearing
Tick this for alarms are cleared after the Automatic clearing delay.
Automatic clearing
delay
Input the automatic clearing delay in seconds.
Show in objects
Display alarms in objects.
Send SNMP
Tick to send SNMP trap in response to alarm.
Table 33
Source Properties - Alarm Tab.
Note:
To setup audio alarms tick the Use audio channel alarm settings box and click on Setup
Audio Alarms.