Vega-MV Router Multiviewer - User Manual
Issue 1 Revision 2
Page 115
© 2017 SAM
Module Menu
Web Interface 7.3
To set the clock source, go to the
Time
tab and select the desired source - Manual, NTP, LTC
or VITC. The setup procedures for each mode are:
Setting
Description
Manual
In this mode,
the time and date of the system clock will be shown and can be
adjusted.
Press the
Get
button to show the current time.
To adjust the time, enter the new time and date in the appropriate
fields and then press the
Set
button.
A battery on the MV-CTL board ensures that time data is retained
should the unit be powered down.
NTP
In this mode,
the time is sourced from an NTP server (or multiple NTP servers can
be entered).
Press the
Add
button to add a new server;
enter the host name or IP address of the new server.
LTC
In this mode,
the time is sourced from the LTC input on the rear panel of the
MV-NET card.
There is nothing to setup here; there just needs to be LTC present for
this to work properly.
If no LTC is present then the system clock will be used.
(If LTC is present but later disappears then the clock will continue
advancing without any discontinuity).
VITC
Here the time can come from VITC that is present on any SDI input.
Select the chosen SDI source number that contains VITC.
If no VITC is present then the system clock will be used.
(If VITC is present but later disappears then the clock will continue
advancing without any discontinuity).
Table 38
Set Time