Vega-MV Router Multiviewer - User Manual
Issue 1 Revision 2
Page 201
© 2017 SAM
Disconnecting MV-EXTPSU3 from a Vega-MV Router Multiviewer
MV-EXTPSU3 Installation
12.4 Disconnecting MV-EXTPSU3 from a Vega-MV Router Multiviewer
.
There are three power supply module slots in a MV-EXTPSU3. To disconnect a whole
MV-EXTPSU3 unit, do the following procedure for each slot.
Preliminaries:
Before disconnecting an MV-EXTPSU3 slot from an Vega-MV unit:
1.
Identify the Vega-MV unit in the rack.
2.
Identify the MV-EXTPSU3 power supply module slot and its corresponding rear
connectors (IEC Mains and DC output).
Procedure:
3.
Unplug the MV-EXTPSU3 slot from its mains supply.
4.
Disconnect the DC power cable at the target Vega-MV frame.
5.
Disconnect the cable at the corresponding MV-EXTPSU3 high-power DC output
D-Type connector.
This has disconnected the Vega-MV unit from the MV-EXTPSU3 slot.
WARNING:
Each MV-EXTPSU3 DC output can provide up 24 A DC.