Vega-MV Router Multiviewer - User Manual
Issue 1 Revision 2
Page 50
© 2017 SAM
Ventilation
Vega-MV Installation 5.1
5.1 Ventilation
5.1.1 Vega-MV
Ventilation is assisted by cooling fans located on the front panel of the Vega-MV unit.
Figure 33 shows the locations of the fans, behind the front of the frame.
Air is pulled in through the ventilation inlets in the front panel, circulated through the unit and
expelled through the rear ventilation outlets, see Figure 34.
Ventilation outlets are located on the top and left side of the unit.
Figure 33 Cooling Fan Locations behind Frame Front Panel
•
Maximum operating ambient temperature must be less than 40°C.
•
The inlet and outlet vents must not be obstructed and should be periodically
cleaned and kept free from the build-up of dust.
•
To maintain adequate cooling, the Vega-MV frame must not be run for more than
two minutes with the front panel open.
•
For ventilation purposes, there must be a gap of at least 50mm (2 inches) for the
front inlet fans and rear outlet grilles.
Figure 34 Vega-MV Ventilation Inlets and Outlets
FAN 1
FAN 2
FAN 3
FAN 4
FAN 5
412mm
(16.2 Inches)