Vega-MV Router Multiviewer - User Manual
Issue 1 Revision 2
Page 131
© 2017 SAM
Object Menu
Web Interface 7.6
Audio Meter W and X Position and Size Configuration
:
Position (vertical slider, C1): 50 and Position (horizontal slider, D1): 5
Size (vertical slider, A1): 90 and Size (horizontal slider, B1): 10
Audio Meter 2
tab settings for meters on the right of the video tile (Meter Y & Z)
Multi-channel metering tick box: Unticked.
Use 2 rows of bars tick box: Tick.
Auto fit tick box: Unticked.
Set Scale label position, Bar colors, Bar labels, etc. as required.
Audio Meter Y
(1st row, channels 9 to 12, top right of tile):
Pair 5, Audio Source: Embedded 9 + 10, Audio format: PCM and 2nd row tick box:
Unticked
Pair 6, Audio Source: Embedded 11 + 12, Audio format: Auto and 2nd row tick box:
Unticked
Audio Meter Z
(2nd row, channels 13 to 16, bottom right of tile):
Pair 7, Audio Source: Embedded 13 + 14, Audio format: Auto and 2nd row tick box: Ticked
Pair 8, Audio Source: Embedded 15 + 16, Audio format: Dolby 5.1 and 2nd row tick box:
Ticked
Audio Meter Y and Z Position and Size Configuration
:
Position (vertical slider, C2): 50 and Position (horizontal slider, D2): 95
Size (vertical slider, A2): 70 and Size (horizontal slider, B2): 8
Note:
The meter Scale Type selected for meter 1 is also used for meter 2 when both meters are
displayed.