Scope and Multimeter Operations
Control Panel and Settings
120
Example:
Selecting 50ms, changes the sweep scale to a 50ms scale. The scale is
“always” divided by 10, therefore each division is incremented by 5ms
.
Figure 9-34
9.9.13 Min, Live and Max Display Panel
When using Expanded mode the Min, Live and Max display panel (
)
shows each channel’s active signal minimum and maximum recorded
measurements and live measurement.
•
Min
- lowest measurement recorded for the signal since the test was activated,
or from the last time Refresh was selected
•
Max
- highest measurement recorded for the signal since the test was
activated, or from the last time Refresh was selected
•
Live
- represents the “live” running average measurement of the signal being
measured
Figure 9-35
9.9.14 Zero Baseline Adjustment
To adjust the vertical position of the zero baseline (0 value) of a trace, either touch
and drag the baseline marker up/down on the screen (
), or open the
trace setup menu to make precise adjustments, see
.
Figure 9-36