Scanner
Data (Viewing PIDs)
69
PID Trigger Status Icons
The icons (below) are used to help you quickly identify the status of individual PID
triggers:
Trigger Setup
To use triggers, they must be turned on, set (configured), and then armed. Use the
following procedures to setup PID triggers. See
for trigger arming/disarming information.
z
To adjust the amount of data collected after a trigger activates:
1.
Select
Properties
from the toolbar.
2.
Highlight one of the
Samples After Trigger
options (0, 5, 10, 20, 50, 100, 200,
500 or 100) (
Figure 5-57
Properties screen
3.
Select
Save
.
z
To turn a trigger on, and set upper/lower trigger limits:
1.
Select the
Menu
icon
on the PID you want to set a trigger on.
2.
Select
Setup
.
The properties dialog box opens (
).
3.
To turn the trigger on select the
Trigger On
checkbox.
4.
Enter the desired upper threshold trigger limit in the
Max
field.
5.
Enter the desired lower threshold trigger limit in the
Min
field.
6.
Select
Save
.
7.
To arm the trigger, see
Figure 5-58
Typical - Trigger Max/Min settings
Icon
Description
Trigger Armed
Trigger has been set (configured) and is armed.
Trigger Activated
Trigger has been activated (upper or lower limit has been met).