HRX-OM-R026
Chapter 2 Name and Function of Parts
HRSH Series
2.4
Operation display panel
2-5
2.4 Operation display panel
The operation panel on the front of the product controls the basic operation
of the product.
Fig. 2-4 Operation display panel
Table 2-4 Operation display panel
No
Description
Function
Reference
page
①
Digital display
(7 segment,
4 digits)
PV
Displays the temperature and pressure of the circulating
fluid and alarm codes.
SV
Displays the set temperature of the circulating fluid and
the set values of other menus.
②
[
o
C
o
F
] lamp
Displays the unit of display temperature (
o
C
or
o
F).
③
[MPa PSI] lamp
Displays the unit of display pressure (MPa or PSI).
④
[REMOTE] lamp
Lights up during remote operation by communication.
⑤
[RUN] lamp
・
Lights up when the product is started and in operation. Goes off when the
product is stopped.
・
Blinks during stand-by for stop (Interval 0.5 seconds).
・
Blinks during independent operation of the pump (Interval 0.3
seconds).
・
Blinks during anti-freezing function (At standby: Interval 2 seconds, At
operation: Interval 0.3 seconds).
・
Blinks during warming up function (At standby: lit on for 0.5 seconds
and off for 3 seconds, At operation: interval 0.3 seconds.)
⑥
[ALARM] lamp
Flashes with buzzer when alarm occurs (Interval 0.3 seconds).
⑦
[ ] lamp
Lights up when the fluid level lowers.
⑧
[
] lamp
Lights up while the run timer or stop timer function is working.
⑨
[
] lamp
Lights up when the product is in automatic operation.
⑩
[RUN/STOP] key
Makes the product start or stop.
⑪
[MENU] key
Shifts the main menu (display screen of temperature) the other
menu (entry of set values and monitor screen).
⑫
[SEL] key
Changes the item in menu and enters the set value.
⑬
[▼] key
Decreases the set value.
-
⑭
[▲] key
Increases the set value.
⑮
[PUMP] key
When the [MENU] and [RUN/STOP] keys are held down
simultaneously, the pump starts running independently.
⑯
[RESET] key
Press
the [▼] and [▲] keys simultaneously. This will stop the alarm
buzzer and reset the [ALARM] lamp.
Keep
the [▼] and [▲] keys pressed down simultaneously for 3
seconds to reset AL46 and AL48.(After resetting AL48,
WAIT(
)
will be displayed and the product cannot run for 40
seconds. Restart 40 seconds later after resetting.
Содержание HRSH090 Series
Страница 8: ...HRX OM R026 Contents HRSH Series...
Страница 20: ...HRX OM R026 Chapter 2 Name and Function of Parts 2 4 Operation display panel HRSH Series 2 6...
Страница 52: ......
Страница 62: ......
Страница 126: ...HRX OM R026 Chapter 5 Display and setting of various functions 5 20 Alarm customizing function HRSH Series 5 64...
Страница 148: ......
Страница 172: ...HRX OM R026 Chapter 8 Control Inspection and Cleaning 8 4 Stop for a Long Time HRSH Series 8 10...
Страница 177: ...HRX OM R026 Chapter 9 Documents HRSH Series 9 1 Specifications 9 5...
Страница 193: ......