-42-
No.PF
※※
-OMA1007
Initial Configuration
○DIP Switch setting
The hardware setting of the Air Management Hub is configured using Setting 1 DIP switch No.1 to 4.
Loosen the display cover screw and open the display cover using a flat head screwdriver.
Refer to the flowing table to set the DIP switches.
AMS
Switch
Position
Switch Number
1
2
3
4
Communication
Method
Regulation Type
NO/NC
Wireless Pairing
Mode
Base type
OFF
Industrial Ethernet
ARS
NC
Refer to Wireless
Network
Configuration
(page
ON
OPC UA
ITV
NO
Remote type
OFF
Wireless Remote
ARS
NC
ON
Standalone
ITV
NO
∗
: Switch Numbers 1 to 3 must be set with the power supply OFF.
∗
: Use an insulated flat-blade screwdriver.