-74-
No.PF
※※
-OMA1007
■
[F14] Zero cut-off setting
When the flow rate and pressure is close to zero, this function forces the display to zero.
The zero cut-off range is 0.0 to 10.0%F.S., and can be set in 1.0%F.S. increments.
<Operation>
Display [F14] by pressing the UP or DOWN button in function selection mode.
Press the SET button.
Move on to select zero cut-off setting (flow rate).
Select zero cut-off setting (flow rate)
Press the UP or DOWN button to select the value of zero cut-off.
∗
: The display above is an example of when [L] is selected for the PF3A801H (1000 L/min type) with the unit switching function.
∗
: If the flow rate does not reach the above value, the display will be zero.
Example: PF3A801H(1000 L/min type)
Press the SET button to set.
Select zero cut-off setting (pressure)
Press the UP or DOWN button to select the value of Zero cut-off.
Press the SET button to set.
Return to function selection mode.
[F14] Zero cut-off setting completed
Move on to select the zero cut-off setting
(pressure).