•Parameter Setting Priority
The Air Management Hub Base parameter "Overwriting parameter by Record Data" controls the priority
for the parameter setting. If enabled, the PROFINET GSDML settings will overwrite the webserver
settings. In the webserver, go to the "System Parameter" section of the Air Management Hub Base to
change this setting.
The Air Management Hub Remote parameter "Module parameter overwrite" controls the priority for the
parameter setting. If enabled, the parameters set using the buttons are prioritised over the parameter AMS
base. This means that the remote parameters will not be overwritten by base parameters when the system
is power cycled or wireless communication is re connected.
In the webserver, go to the "System Parameter" section of the Air Management Hub Remote to change
this setting.