-75-
No.PF
※※
-OMA1007
●
Displayable flow rate range
Zero cut-off
set
Zero cut-off
range
Displayable flow range
AMS20
AMS30
AMS40
AMS60
0.0
∗
0%F.S.
0 to 525 L/min
0 to 1050 L/min
0 to 2100 L/min
0 to 4200 L/min
1.0
0 to 1%F.S.
5 to 525 L/min
(Displays 0 when
the value is below
5 L/min)
10 to 1050 L/min
(Displays 0 when
the value is below
10 L/min)
20 to 2100 L/min
(Displays 0 when
the value is below
20 L/min)
40 to 4200 L/min
(Displays 0 when
the value is below
40 L/min)
2.0
0 to 2%F.S.
10 to 525 L/min
(Displays 0 when
the value is below
10 L/min)
20 to 1050 L/min
(Displays 0 when
the value is below
20 L/min)
40 to 2100 L/min
(Displays 0 when
the value is below
40 L/min)
80 to 4200 L/min
(Displays 0 when
the value is below
80 L/min)
3.0
0 to 3%F.S.
15 to 525 L/min
(Displays 0 when
the value is below
15 L/min)
30 to 1050 L/min
(Displays 0 when
the value is below
30 L/min)
60 to 2100 L/min
(Displays 0 when
the value is below
60 L/min)
120 to 4200 L/min
(Displays 0 when
the value is below
120 L/min)
4.0
0 to 4%F.S.
20 to 525 L/min
(Displays 0 when
the value is below
20 L/min)
40 to 1050 L/min
(Displays 0 when
the value is below
40 L/min)
80 to 2100 L/min
(Displays 0 when
the value is below
80 L/min)
160 to 4200 L/min
(Displays 0 when
the value is below
160 L/min)
5.0
0 to 5%F.S.
25 to 525 L/min
(Displays 0 when
the value is below
25 L/min)
50 to 1050 L/min
(Displays 0 when
the value is below
50 L/min)
100 to 2100 L/min
(Displays 0 when
the value is below
100 L/min)
200 to 4200 L/min
(Displays 0 when
the value is below
200 L/min)
6.0
0 to 6%F.S.
30 to 525 L/min
(Displays 0 when
the value is below
30 L/min)
60 to 1050 L/min
(Displays 0 when
the value is below
60 L/min)
120 to 2100 L/min
(Displays 0 when
the value is below
120 L/min)
240 to 4200 L/min
(Displays 0 when
the value is below
240 L/min)
7.0
0 to 7%F.S.
35 to 525 L/min
(Displays 0 when
the value is below
35 L/min)
70 to 1050 L/min
(Displays 0 when
the value is below
70 L/min)
140 to 2100 L/min
(Displays 0 when
the value is below
140 L/min)
280 to 4200 L/min
(Displays 0 when
the value is below
280 L/min)
8.0
0 to 8%F.S.
40 to 525 L/min
(Displays 0 when
the value is below
40 L/min)
80 to 1050 L/min
(Displays 0 when
the value is below
80 L/min)
160 to 2100 L/min
(Displays 0 when
the value is below
160 L/min)
320 to 4200 L/min
(Displays 0 when
the value is below
320 L/min)
9.0
0 to 9%F.S.
45 to 525 L/min
(Displays 0 when
the value is below
45 L/min)
90 to 1050 L/min
(Displays 0 when
the value is below
90 L/min)
180 to 2100 L/min
(Displays 0 when
the value is below
180 L/min)
360 to 4200 L/min
(Displays 400 when
the value is below
10 L/min)
10.0
0 to 10%F.S.
50 to 525 L/min
(Displays 0 when
the value is below
50 L/min)
100 to 1050 L/min
(Displays 0 when
the value is below
100 L/min)
200 to 2100 L/min
(Displays 0 when
the value is below
200 L/min)
400 to 4200 L/min
(Displays 0 when
the value is below
10 L/min)
∗
: The zero-cut-off range of the accumulated value should be 1%F.S. or more. However, please note that if the zero-cut-off set
value is 0.0, any value below 1%F.S. will be cut.
Содержание AMS20
Страница 1: ...No PF OMA1007 PRODUCT NAME Air Management System MODEL Series Product Number AMS20 AMS30 AMS40 AMS60...
Страница 13: ...12 No PF OMA1007 Model Indication and How to Order Air Management System Standby E P regulator type...
Страница 14: ...13 No PF OMA1007 Air Management System Standby regulator type...
Страница 40: ...39 No PF OMA1007...
Страница 124: ...123 No PF OMA1007 EXA1 60 PN EN...
Страница 126: ...125 No PF OMA1007 EXA1 60 SA Refer to separate operation manuals for other AMS components...