OOPC UA nodes are user configurable and can be imported and exported via a csv file. Refer to the
Process data map to configure user nodes.
The "Write Enable" check box enables outputs to be written to by OPC UA.
The "Buffer Enable" check box enables buffering of the selected node.
An adjustable data buffer is available via OPC UA for up to 1800 bytes of data and a sampling rate of
100 ms or longer.
Parameters
Description
Data buffer Enable or Disable
The data buffer array can be enabled or disabled for each OPC UA
node.
Historical Data Buffer Sampling Cycle
Sampling cycle time for the buffer. The parameter is applicable for all
nodes which enabled the data buffer.
Number of data blocks
The number of points stored in the buffer. The parameter is
applicable for all nodes with the data buffer enabled.
The time stamp is LDAP/Win32 format. To convert from the buffer data to a time, the bytes must first be
combined. The resulting decimal value is the number of 100 ns passed since January 1st, 1601.
The example is shown in the following table.
Data [0]
Data [1]
Data [2]
Data [3]
Dec
472
38370
12261
55367
Hex
1D8
95E2
2FE5
D847
Combine
1D895E22FE5D847
DEC
133020987706169000
Содержание AMS20
Страница 1: ...No PF OMA1007 PRODUCT NAME Air Management System MODEL Series Product Number AMS20 AMS30 AMS40 AMS60...
Страница 13: ...12 No PF OMA1007 Model Indication and How to Order Air Management System Standby E P regulator type...
Страница 14: ...13 No PF OMA1007 Air Management System Standby regulator type...
Страница 40: ...39 No PF OMA1007...
Страница 124: ...123 No PF OMA1007 EXA1 60 PN EN...
Страница 126: ...125 No PF OMA1007 EXA1 60 SA Refer to separate operation manuals for other AMS components...