-25-
No.PF
※※
-OMA1007
(3)
Connection to each device
Refer to the following instructions when device maintenance/replacement is required.
AMS components and signals connect to the four connectors on the rear of the Air Management Hub.
All connections are M12 A-coded. The following table shows the functions of each port.
Port
Function
1
Connection to Residual Pressure Relief Valve
2
Connection to standby regulator
3
Digital input signals for standby and isolation
4
User configurable port (IO-Link or DIO)
AMS##A Series
AMS##B Series
•Connection to Residual Pressure Relief Valve (VP)
Hub side: M12 5-pin A-coded (Socket)
Connector
Pin No.
Signal
Details
1
NC
Not connected
2
NC
Not connected
3
0 V
0 V
4
Output
Output
5
NC
Not connected
VP side: M12 3-pin A-coded (Plug)
Connector
Pin No.
Signal
Details
3
0 V
0 V
4
+
Input
5
FE
Ground