-71-
No.PF
※※
-OMA1007
■
[F 3] Select digital filter
The digital filter can be selected to filter the flow rate and pressure measurement.
Output chattering or display flicker in measurement mode can be reduced by setting the digital filter.
<Operation>
Display [F 3] by pressing the UP or DOWN button in function selection mode.
Press the SET button.
Move on to select digital filter (flow rate).
Select digital filter (flow rate)
Press the UP or DOWN button to select the flow rate digital filter.
Press the SET button to set.
Move on to select digital filter (pressure).
Select digital filter (pressure)
Press the UP or DOWN button to select the pressure digital filter.
Digital filter set range: 0.00 to 30.00 [s]
Press the SET button to set.
Return to function selection mode.
[F 3] Digital filter setting completed
∗
: Each set value is a guideline for 90% response time.
∗
: Both the switch output and flow display are affected.