-28-
No.PF
※※
-OMA1007
LED indicator
Air Management Hub (Base type)
LED
LED colour
PROFINET
EtherNet/IP
TM
SF/MS
OFF
Normal operation or the power supply is
OFF.
Power supply is OFF.
Orange flashing
Node flashing test command received.
Internal communication error in wireless
adaptor.
-
Green ON
-
Normal operation.
Green flashing
Power supply voltage is abnormal.
Short circuit of power supply in input or
output port.
Excessive I/O setting inputs/outputs.
EtherNet/IP
TM
connection is not
established.
Red flashing
Pairing mode. (synchronized with BF)
Power supply voltage is abnormal.
Short circuit of power supply in input or
output port.
Excessive I/O setting inputs/outputs.
Internal communication error in wireless
adaptor.
Pairing mode. (synchronized with NS)
Red ON
Non-restorable error is detected. (e.g. Hardware failure)
BF/NS
OFF
PROFINET communication established.
-
Green ON
OPC mode operating.
EtherNet/IP
TM
communication is
established.
Green flashing
-
EtherNet/IP
TM
communication is not
established.
Red flashing
Paring mode. (synchronized with SF)
EtherNet/IP
TM
communication timeout.
Pairing mode. (synchronized with MS)
Red ON
•Cable not connected between PLC
and AMS Hub.
•Wrong device name on PROFINET.
•Wrong IP address or not configured.
•Wrong GSDML file.
•Configuration mismatch between PLC
and actual connection.
Duplicated IP addresses are detected.
PWR
OFF
No power supplied.
Green flashing
Power supply voltage is abnormal.
Green ON
Power supply voltage is in the specification.
MODE
OFF
During initialization.
Green ON
Operation mode.
Green flashing
Waiting for Standby signal.
Orange ON
Standby mode.
Orange flashing
Isolation mode.
SIG
OFF
No signal received.
Green flashing
Input port short circuit.
Green ON
Standby input signal ON.
Orange flashing
Isolation input signal ON.
Orange ON
Standby input and Isolation input are both ON.
Содержание AMS20
Страница 1: ...No PF OMA1007 PRODUCT NAME Air Management System MODEL Series Product Number AMS20 AMS30 AMS40 AMS60...
Страница 13: ...12 No PF OMA1007 Model Indication and How to Order Air Management System Standby E P regulator type...
Страница 14: ...13 No PF OMA1007 Air Management System Standby regulator type...
Страница 40: ...39 No PF OMA1007...
Страница 124: ...123 No PF OMA1007 EXA1 60 PN EN...
Страница 126: ...125 No PF OMA1007 EXA1 60 SA Refer to separate operation manuals for other AMS components...