-64-
No.PF
※※
-OMA1007
•AMS Remote
Byte
Bit
Note
7
6
5
4
3
2
1
0
0
Accumulated flow [high word]
Unit: 10 L
1
2
Accumulated flow [low word]
3
4
Instantaneous flow [high byte]
Unit: L/min
5
Instantaneous flow [low byte]
6
Fluid temperature [high byte]
Unit: 0.1
o
C
7
Fluid temperature [low byte]
8
Pressure [high byte]
Unit: kPa
9
Pressure [low byte]
10
System
error
Error
Forced
output
Pressure
diagnostic
Temperature
diagnostic
Flow rate
diagnostic
Flow
reference
Condition
Accumulated
flow unit
11
AMS status
00HEX: Initialising
01HEX: Operation mode
11HEX: Forced
Operation mode
from button
02HEX: Waiting for
standby signal
03HEX: Standby mode
13HEX: Forced Standby
mode from
button/OPC UA
23HEX: Force Standby
mode from
PLC/OPC UA
04HEX: Isolation mode
14HEX: Force Isolation
from button/web
24HEX: Force isolation
mode from
PLC/OPC
UA/Digital Input