-31-
No.PF
※※
-OMA1007
Air Management Hub (Port status)
Port1(VP)
LED
LED colour
Operation
VP
(CQ_1)
OFF
Output signal OFF.
Orange ON
Output signal ON.
Red ON
Short circuit detected.
Port2(ITV/ARS)
LED
LED colour
Operation
ITV/ARS
(CQ_2)
OFF
Output signal OFF.
Orange ON
Output signal ON. (ARS)
Green flashing
(1 Hz)
IO-Link device not connected.
Green flashing
(2 Hz)
Connected device matching error.
Device process data mapping error.
Data storage writing error.
Green ON
IO-Link device in communication.
Red ON
Short circuit detected. (24 V or C/Q)
Port3(Standby signal)
LED
LED colour
Operation
Standby
signal
(CQ_3)
OFF
Input signal OFF.
Orange ON
Input signal ON.
Red ON
Short circuit detected. (24 V)
Port3(Isolation signal)
LED
LED colour
Operation
Isolation
signal
(IQ_3)
OFF
Input signal OFF.
Orange ON
Input signal ON.