-35-
No.PF
※※
-OMA1007
System overview
The AMS consists of three base components.
•Standby E/P regulator or Standby regulator: Electrical or manual adjustment of standby pressure. Standby
pressure is activated by electrical signal from the Air Management Hub.
•Air Management Hub: Measures flow rate, pressure and temperature, manages network communication
and controls the composed devices.
•Residual Pressure Relief Valve: Exhaust the downstream pressure and is connected to the AMS Hub.
The AMS components are compatible with SMC’s modular AC-D F.R.L. system and can be combined with
existing installations.
Two versions of the Air Management Hub are available, base type and remote type.
These can be combined to create a wireless network of up to 11 Air Management Hubs (1 wireless base +
10 wireless remotes). Data for all connected AMS wireless remotes is available on the network via the
AMS wired/base using Fieldbus and OPC UA.
1. Air Management Hub: Base type (EXA1-##-PN/EXA1-##-EN)
The Air Management Hub wired/base version comes with Industrial Ethernet and OPC UA for data
communication and webserver for parameter setting.
A wireless adapter can be connected to use the Air Management Hub as a wireless base. AMS wireless
remotes can then be paired to the AMS wireless base.
Содержание AMS20
Страница 1: ...No PF OMA1007 PRODUCT NAME Air Management System MODEL Series Product Number AMS20 AMS30 AMS40 AMS60...
Страница 13: ...12 No PF OMA1007 Model Indication and How to Order Air Management System Standby E P regulator type...
Страница 14: ...13 No PF OMA1007 Air Management System Standby regulator type...
Страница 40: ...39 No PF OMA1007...
Страница 124: ...123 No PF OMA1007 EXA1 60 PN EN...
Страница 126: ...125 No PF OMA1007 EXA1 60 SA Refer to separate operation manuals for other AMS components...