11.1 Commissioning malfunctions
Covvissioning volfunctions
Molfunction
Couse
Revedy
Displacement volume and/
or delivery pressure too low
without supply lines connected
Air in the pump element
• Vent and fill according to Chapters 7.1 and 7.3, Initial commissioning
Driveshaft rotating in wrong direction
Driveshaft speed is too low
• Check electrical connections and voltage
• Remove foreign substances if agitator or pump element is jammed
• Replace the defective motor if necessary
No delivery (with pipe con-
nections and supply lines not
yet connected)
Air in the pump element
Pump element set too low
Pump element not hooked in properly
• Vent the pump element
• Set notch position 0 (max. delivery rate)
• Remove and install the pump element as instructed in Chapters 12.1
and 12.2
Motor does not start
Grease too stiff
• Check electrical connections
• Clean venting slots on motor
• Replace geared motor if necessary