![SKF LINCOLN FB Series Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/skf/lincoln-fb-series/lincoln-fb-series_operating-instructions-manual_1287064068.webp)
EN
6. Assembly
- 68 -
951-180-076-EN
Version 0y
Equipotential bonding connection
(screw M6)
Equipotential bonding connection (screw M6)
PE cable provided by customer
PE cable provided by customer
1
3
2
4
5
1 2
3
4
5
• Loosen the clamping screw (
2
) on the
ground terminal (
1
).
• Insert the cable end of the standard
grounding cable (
3
) into the ground
terminal.
• Tighten the clamping screw (
2
).
• Check that the grounding cables (
4
and
5
) are securely connected, tighten cable
glands if necessary.
• Perform PE continuity test.
Fig.19
Grounding of ATEX vultiline puvp units