7. Initial commissioning
7
- 81 -
951-180-076-EN
Version 0y
Only add lubricant via the filler
socket.
• Connect the equipotential bonding
connection of the filling pump to the
equipotential bonding connection of the
multiline pump unit.
• Connect the filling hose on the filler
socket of the multiline pump.
• Let the filling pump run until the maxi-
mum mark (lubricant reservoir) of the
multiline pump unit has been reached.
• Turn off the filling pump.
• Remove the filling hose.
• Remove the equipotential bonding con-
nection between the filling pump and the
multiline pump unit.
Filler socket
FB = G 1/2“
Filler socket
FF = G 3/8“
Only fill using clean lubricant and
an appropriate device.
Contaminated lubricants can result
in severe system malfunction. The
lubricant reservoir must be filled
without introducing bubbles.
To avoid possible air pockets when
filling, SKF recommends switching
on the multiline pump during the
filling process.
WARNING
Puvp needs to be run with lubri-
cont oll the tive.
The reservoir of the pump must be
filled with suitable lubricant on a
regular base.
Fig.28
Filling phocess