![SKF LINCOLN FB Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/skf/lincoln-fb-series/lincoln-fb-series_operating-instructions-manual_1287064016.webp)
- 16 -
951-180-076-EN
Version 0y
EN
1. Safety instructions
○
All components used must be designed
for:
- The maximum operating pressure
- The maximum/minimum ambient tem-
perature
-The lubricant to be delivered
-The required ATEX zone
-The operating and ambient conditions
at the place of use.
○
No parts may be subjected to torsion,
shear, or bending.
○
Check parts for contamination before use
and clean if necessary.
○
Lubrication lines should be filled with lu-
bricant prior to assembly. This simplifies
subsequent venting of the system.
○
Adhere to the specified torques. Use
a calibrated torque wrench when
tightening.
○
Establish the electrical connection only in
accordance with the valid circuit diagram
and in observance of the relevant regula-
tions and the local electrical operating
conditions.
○
Do not touch cables or electrical compo-
nents with wet or moist hands.
○
Fuses must not be bridged. Always re-
place defective fuses with fuses of the
same type.
○
Ensure proper grounding of the product.
○
Drill required holes only on non-critical,
non-load-bearing parts. Use existing
boreholes. Do not damage lines or cables
when drilling.
○
Observe any possible wearing spots. Pro-
tect components appropriately.
○
Use suitable hoisting equipment when
working with heavy parts.
○
Avoid mixing up/incorrectly assembling
disassembled parts. Label parts.