![SKF LINCOLN FB Series Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/skf/lincoln-fb-series/lincoln-fb-series_operating-instructions-manual_1287064025.webp)
1
- 25 -
951-180-076-EN
Version 0y
EN
1. Safety instructions
Residual risk
Possible in
lifecycle
Avoidance / Remedy
Generation of electrostatic charges or sparks by
dropping of parts
C, D, E, F, G
Secure parts against falling. if necessary, cover parts to avoid sparking
Introduction of catalytic, unstable, or pyro-
phoric substances into the potentially explosive
atmosphere
C, D, E, F, G
Ensure that none of these substances enter the potentially explosive atmosphere; have
all substances approved by the operator in advance
Use of isolating amplifiers, for example to oper-
ate a capacity sensor in the potentially explo-
sive atmosphere
C, D, G
Install isolating amplifiers only outside of the potentially explosive atmosphere
Incorrect mounting position Loss of proper fill
level reporting function
C, D, G
Follow the prescribed mounting position (± 5°) Correct the mounting position if
necessary
Use of an unsuitable lubricant for low tempera-
tures; at low temperatures, excessive lubricant
viscosity can cause loss of pump function
C, D
Use only lubricants suitable for the specific operating temperature in each case
Lifecycles: A = Transport, B = Assembly, C = Initial commissioning, D = Operation, E = Cleaning, F = Maintenance, G = Malfunction, repair,
H = Shutdown, K = Disposal