6. Assembly
6
- 65 -
951-180-076-EN
Version 0y
6.5 Electrical connection
WARNING
Electric shock
Electrical connections for the
product may only be established
by qualified ATEX personnel au-
thorized to do so by the operator.
The local electrical operating con-
ditions and local regulations (e.g.,
DIN, VDE) must be observed.
NOTE
In motor drive positions “A“ and “E,”
the motor can only be connected
counterclockwise!
Observe the guidelines in DIN EN 60034-1
(VDE 0530-1) for operation at the limits of
the B ranges (combination of ±10% voltage
deviation and +3/-5% frequency deviation).
This applies especially with regard to heat-
ing and deviations in operating parameters
from the ratings on the motor rating plate.
The limits must never be exceeded.
Be sure to connect the motor so as to
guarantee a continuously safe electrical
connection (no protruding wire ends); use
the assigned cable end fittings (e.g., cable
lugs, wire end ferrules). Select connecting
cables conforming to DIN VDE 0100, taking
into account the rated current and the con-
ditions of the specific system (e.g., ambient
temperature, type of routing, etc. in accor-
dance with DIN VDE 0298-4).
Consult the terminal diagram in the
terminal box for details regarding electrical
connection of the motor to the power
supply, especially terminal and connector
pin assignment.
WARNING
Electric shock / dovoge to puvp
votor
The available mains voltage
(supply voltage) must match the
specifications on the rating plate
of the motor or of the electrical
components.
It may be connected only via a safe
galvanic isolation (PELV).
Check the fuse protection of the
electrical circuit.
Use only fuses with the prescribed
current intensity.
Monitoring equipment that has
been triggered (e.g., motor circuit
breaker/fuse) must not automati-
cally switch on again.