EN
6. Assembly
- 66 -
951-180-076-EN
Version 0y
WARNING
Moins connection for explosion-
proof votors
A mains connection in a potentially
explosive atmosphere requires a
motor circuit breaker or equivalent
protective device, such as a PTC
thermistor with triggering device.
This must be indicated on the
motor rating plate together with
release time
t
A
.
IMPORTANT NOTE
The electrical characteristics of the motor,
such as rated voltage, rated frequency,
and rated current are specified on the
motor rating plate and in the manufactur-
er's operating instructions. The informa-
tion contained therein must be observed.
1
WARNING
Dovoge to puvp votor/puvp
When establishing the electrical
connection of the pump motor, be
mindful of the correct direction of
rotation. The direction of rotation
must match the arrow on the
motor.
Connect the power cables in
such a way that no forces are
transferred to the product
(stress-free connection).
Connect the pump motor in accordance with
the motor connection data sheet (
1
) from
the motor manufacturer. It is located in the
motor’s terminal box (Fig. 18).
IMPORTANT NOTE
Use only original cover fittings and original
cable glands from the motor manufacturer.
Fig.18
Motor tervinol box with doto sheet