Fig. 4-4 Example of User-defined Mode Setting
In the user-defined mode, press the ENTER key
to enter the Level 2 menu. The
Level 2 menu only displays 32 user-defined parameters in the F11 group. The user can
enter the F11 group from the full menu mode to set these function codes.
After the function codes are defined in the F11 group, enter the user-defined mode.
Then we can see F00.07 defined by the first function code F11.00, F00.09 defined by the
first function code F11.01, and so on to F11.31, 32 in total. Function code modification in
the Level 3 menu is equivalent to that in the full menu mode, and the modification method
is also the same.
In the Level 2 menu of the user-defined mode, press the increment
or decrement
key on the keyboard to change the function code defined by F11.00 to that defined by
F11.31.
When the right shift key
is pressed in the Level 2 menu, the cursor will not shift.
Press the ENTER key
to enter the Level 3 menu. If the displayed function code is
modifiable currently, the lowest bit indicated by the cursor will flicker. Parameter
modification is the same as that in the Level 3 menu under the full menu mode. After