User Manual of A90 Series Inverter
190
14
Valid
Valid
Invalid
Valid
Multi-segment
speed 13
F08.12
15
Valid
Valid
Valid
Invalid
Multi-segment
speed 14
F08.13
16
Valid
Valid
Valid
Valid
Multi-segment
speed 15
F08.14
Precautions for setting:
★
The start and stop in multi-segment speed operation depends on the function code
F00.02.
★
The acceleration/deceleration time in multi-segment speed operation can be
controlled by the external terminal with the acceleration/deceleration time
function.
The direction of multi-segment speed operation is controlled by the terminals F/R and
RUN.
Function
code
Function code
name
Parameter description
Unit
Default
setting
Attribute
F08.15
Simple PLC
running mode
0: stop after a single run
1: stop after a limited number
of cycles
2: run at the last segment
after a limited number of
cycles
3: continuous cycles
0
●
F08.16
Limited number of
cycles
1 - 10000
1
●
In addition to the multi-segment speed mode, it also has the simple PLC function.
There are four running modes in total, as detailed in Table 7-11.
Table 7-11 Details of PLC Running Mode
F08.15
Description
0
The inverter will be stopped after running in the last segment.
1
The inverter will run cyclically and be stopped after the set cycles. The number
of cycles depends on the function code F08.16.
2
The inverter will run cyclically and keep the speed of the last segment after
running in the last segment, until a stop command is received. The number of
cycles depends on the function code F08.16.
3
The inverter will continue cyclic operation until a stop command is received.