![Simrad SH80 - REV C Скачать руководство пользователя страница 111](http://html1.mh-extra.com/html/simrad/sh80-rev-c/sh80-rev-c_installation-manual_1279224111.webp)
Start--up procedures
95
851--164300 / C
9.5 Starting up the Wheelhouse Units
Introduction
If the AC mains plug on the SH80 Sonar Processor Unit has been
disconnected, the initial start of the sonar must be made by pressing
the start switch
S101
. This switch is located behind the small lid
on the front panel of the Sonar Processor Unit.
The AC mains plug must be disconnected when the vessel is in dry
dock etc. This in order to prevent inadvertent use of the sonar,
which is such case could cause serious damage to the system.
Start up
Observe the following procedure for starting up the sonar.
1
Connect the Sonar Processor Unit’s AC mains plug.
2
Press the
Power
button on the display unit.
- Check that the text
Sync...
appears on the display
.
after
approximately 10 seconds.
3
Locate the start switch
S101
behind the front door on the
front panel of the Processor Unit, and press the switch for
approximately two seconds.
4
Check that the green LED beside the
Power
button on the
Sonar Operating Panel starts blinking.
- The sonar is now loading up the sonar programme, and
after approximately two minutes, the sonar menu will be
displayed.
S101
(CD7010)
Figure 34 Location
of switch S101
Содержание SH80 - REV C
Страница 2: ......
Страница 14: ...Simrad SH80 X 851 164300 C Blank page...
Страница 61: ...Transceiver unit 45 851 164300 C Figure 13 Mounting the Transceiver Unit CD3110A...
Страница 186: ...Simrad SH80 170 851 164300 C 12 3 Installation drawings The SH80 installation drawings are provided on the next pages...
Страница 195: ...Installation remarks 179 851 164300 C Party Date Signature Party Date Signature Party Date Signature...
Страница 196: ...Notes...
Страница 197: ...Notes...
Страница 200: ......