Cable layout and connections
63
851--164300 / C
1
Run the 100 m data cable from the wheelhouse and down to
the sonar room.
Note
The data cable from the wheelhouse to the sonar room must be
supported and protected along its entire length using conduit
and/or cable trays. The cable must not be installed in close
proximity to high-power cables antenna cables or other possible
sources of interference.
This cable must not be spliced. If it is not long enough, or if an
accident occurs with it, contact your local dealer or Simrad for
advice.
2
Locate the RJ-45 connector (included with the delivery), and
mount the connector
J5
as shown on the cable connection
drawing.
3
Do
not
connect the plug to the Sonar Interface Unit.
→
Cable details on page 161
→
The installation of this cable into the Transceiver Unit is
described later. See page 66.