Heavy units may be equipped with lifting lugs for transportation
by crane within the workshop or installation area. Before you
use a crane:
• You must check the applicable weight certi
fi
cate for the crane.
• You must check the security of the lifting lugs.
Ensure that all available lifting lugs are used. Ensure the unit
remains under control during the operation to avoid damage to
the unit, equipment or personnel.
Heavy units may be transported using a forklift truck. Special
attention must then be paid to the position of the unit’s centre of
gravity. The units must be properly secured to the truck.
Storage prior to installation or use
When a system, a unit or a spare part has been delivered to
the customer, it may be subject to long time storage prior
to installation and use. During this storage period, certain
speci
fi
cations must be met. The equipment must be preserved
and stored in such a way that it does not constitute any danger
to health, environment or personal injury.
1
The equipment must be stored in its original transportation
crate.
2
Ensure that the units are clearly separated in the shelves and
that each unit is easily identi
fi
able.
3
The crate must not be used for any purpose for which it was
not intended (eg. work platform etc.).
4
The crates must not be placed on top of each other, unless
speci
fi
c markings permit this.
5
The crates must not be placed directly on a dirt-
fl
oor.
6
Do not open the crate for inspection unless special
circumstances permit so.
• “Special circumstances” may be suspected damage to the
crate and its content, or inspections by civil authorities.
• If any units are damaged, prepare an inspection report
stating the condition of the unit and actions taken.
Describe the damage and collect photographic evidence
if possible. Re-preserve the equipment.
• If the units are not damaged, check the humidity
absorbing material. If required, dry or replace the
bags, then re-pack the unit(s) according to the packing
instructions.
7
If the crate has been opened, make sure that is it closed
and sealed after the inspection. Use the original packing
material as far as possible.
16