Transducer Installation
Cable gland for steel hulls
This cable gland kit is designed for steel vessels. It must be
welded to the hull plates.
(CD17008A)
ø35
ø65
A
A
B
C
C
D
E
F
(A) = Steel conduit
(B) = Stuffing tube, DNV approved carbon steel st52.3
(C) = Washers
(D) = Rubber gasket
(E) = Packing nipple. Make sure that you do not damage the
transducer cable by tightening the packing nipple too hard!
(F) = Cable to the echo sounder (or a junction box)
The cable gland kit includes all of the necessary parts needed to
install the unit except screws.
Simrad recommends that a one inch steel conduit (that the
transducer cable will be run through) with an inside threaded
diameter of three-quarter inches is welded to the gland’s stuf
fi
ng
tube. The conduit must extend to above the vessel’s water line.