Cable layout
The
New line
feature is not used on the ES60.
Cable details:
GPT Event and New line
on page 61.
Additional information:
GPT Auxiliary connector
on page 96
ES60/C20 - Alarm output
This output allows you to implement an alarm sounder or lamp
to indicate an echo sounder alarm condition. The output on the
General Purpose Transceiver only provides a positive (+5 Vdc)
level unable to power any external devices directly. If you wish
to use this function, you must therefore design an external device
containing an opto-coupler or relay to sense the alarm output.
This device can then trigger secondary devices such as sounders
or lamps. The cable, devices and mounting material must be
provided by the installation shipyard. If more than one General
Purpose Transceiver (GPT) is used, the alarm output on only
one of them is used.
Cable details:
GPT Alarm output
on page 62.
Additional information:
GPT Auxiliary connector
on page 96
ES60/C21 - Ethernet cable between Ethernet
switch and transceivers
When two or more General Purpose Transceivers are used,
these are connected to the computer by means of an Ethernet
switch. Cable
ES60/C14
is used between the switch and the
computer, this is a “straight” ethernet cable. For each transceiver,
one
ES60/C20
cable is used. Each of these are also “straight”
ethernet cables.
Cable details:
Ethernet cable with RJ45, “straight”
on page 52.
ES60/C22 - Supply power to Ethernet switch
Most Ethernet switches are supplied with a separate power
supply.
Cable details:
Commercial power supply
on page 48.
Cable details
This chapter provides details cable drawings offering cable
speci
fi
cations and termination information.
Cables
Generic RS-232 Serial line cable
on page 47
Commercial power supply
on page 48
External power supply for transceiver
on page 49
230 Vac power cable
on page 50
Ship’s ground
on page 51
304699/A