Introduction
8
The storage room/area must be dry, with a non-condensing
atmosphere. It must be free from corrosive agents.
9
The storage area’s mean temperature must not be lower than
-30° C, and not warmer than +70° C. If other limitations
apply, the crates will be marked accordingly.
Note
Transducers must not be stored in temperatures below -20°
C, or higher than +60° C.
10
The crate must not be exposed to moisture from
fl
uid
leakages.
11
The crate must not be exposed to direct sunlight or excessive
warmth from heaters.
12
The crate must not be subjected to excessive shock and
vibration.
13
If the unit contains normal batteries, these may have been
disconnected/isolated before the unit was packed. These
must only be reconnected before the installation starts. Units
containing batteries are marked.
Caution
Units containing lithium or alkaline batteries must
be handled separately and with care. Such units are
marked accordingly. Do not attempt to recharge
such batteries, open them or dispose of them by
incineration. Refer to the applicable product data
sheets.
Inspection
An inspection must be carried out immediately after the unit(s)
have arrived at their destination.
1
Check all wooden or cardboard boxes, plastic bags and
pallets for physical damage. Look for signs of dropping,
immersion in water or other mishandling.
2
If damage is detected externally, you will have to open the
packaging to check the contents. Request a representative of
the carrier to be present while the carton is opened, so any
transportation damage can be identi
fi
ed.
3
If any units are damaged, prepare an inspection report
stating the condition of the unit and actions taken. Describe
the damage and collect photographic evidence if possible.
Send the inspection report to Simrad as soon as possible.