Cable layout
Single beam transducer to split beam
transceiver
This is the termination of the transducer cable from a single
frequency, single beam transducer to the socket on a split beam
General Purpose Transceiver Unit (GPT). The other end of the
cable is permanently
fi
xed to the transducer.
M
E
F
J
H
D
C
K
L
A
B
N
Transducer
cable
E
A
B
C
D
H
J
F
Junction Box (1:1)
(Optional)
GPT Transducer
socket
Screen
Connect to plug housing
W802-9
Rev.A
Single frequency, single beam, to split beam transceiver, termination
If you need to splice the transducer cable, it is very important to
use the correct cable, and to avoid ground loops. We strongly
recommend the use of a junction box. We also recommend that
you install the transducer cable in a steel conduit.
Related topics
Cable splicing
on page 140
Steel conduit
on page 140
GPT Transducer plug connection
on page 105