Simrad ES60
Note
The location of the transducer and/or protection blister must be
noted on the vessel’s docking plan for future reference.
Wiring
All cables running between system cabinets located in different
rooms and/or on different decks must be supported and protected
along their entire lengths using conduits and/or cable trays. Note
that the cables must not be installed in the vicinity of high-power
supplies and cables, antenna cables or other possible sources
of interference.
Whenever possible, transducer cables must be run in steel
conduits.
For more detailed information about cables and wiring, refer to
Basic cable requirements
on page 80