Cable layout
Cable between PI44/54 and echo sounder
This cable is used to provide a two-way communication between
the echo sounder and a PI44 or PI54 catch monitoring system.
W620G
Rev.A
Communication between PI44/54 and echo sounder
1
5
5
3
3
7
2
2
6
4
8
9
Tx - Ground
Rx - Data in
Rx - Ground
Tx - Data out
Not used
Receive (Rx)
Transmit (Tx)
Ground
Not used
Not used
Not used
Not used
Plug and connector manufacturer: www.conxall.com
A small circular marker
identifies pin 1.
(1)
(2)
(3)
(4)
(8)
(5)
(6)
(7)
(9)
View:
Looking
the
socket on the
rear side of the
cabinet = Wiring
view of
on male and female
plugs.
into
cable side
NMEA connector
on PI system
Suitable serial line
connector on echo
sounder computer
White
Colours below are those used on the serial line
cable provided with the PI system.
Brown
Yellow
Green
• Conductors: 9 x 2 x 0.5 mm2
• Screen: Screened twisted pairs and overall braided
• Voltage: 60 V
• Maximum diameter: Limited by the plugs
304699/A
65