Instruction Manual OilGuard 2 Ex
Troubleshooting
92
13003E/3
The following warning messages can be displayed:
WARNING
DESCRIPTION
POSSIBLE CAUSES
V IN
The input voltage for the op-
erating electronics is outside
the permitted range (18-30
VDC).
The service voltage is faulty.
ADJUST FAULT
The adjustment could not be
performed.
The instrument is soiled.
The nominal value for the ad-
justment does not match the
value of the medium.
CURRENT 1
Current output 1 is disturbed.
Terminals are open.
Interruption of the current loop
of the measuring value output.
EXTERNAL
(Name ext.in.)
An external fault is signaled
via a digital input.
The user can then con-
figure this as a warning, fault
or prio fault.
External fault.
SERVICE
Shows when service work is
due.
Service work is due.
VERS.SD CARD
The data on the microSD card
does not match the current
software.
Update was performed incor-
rectly.
WATCHDOG
The internal fault monitoring
has been actuated.
The program has been re-
started.
Program crash.
Table 3: Possible warning messages